Inquiry
Form loading...
China Suppliers Factory for Industrial Water-Cooled Chiller – Efficient Cooling Solutions for CO2 Lasers
Hot Products

China Suppliers Factory for Industrial Water-Cooled Chiller – Efficient Cooling Solutions for CO2 Lasers

The Water-Cooled Chiller is a vital component in industrial and commercial HVAC systems, designed to deliver efficient cooling for a range of applications, including air conditioning, manufacturing processes, and refrigeration. This system works by extracting heat from a liquid, usually water, and transferring it to a water source such as a cooling tower, where the heat is effectively dissipated into the environment. As leading China suppliers and manufacturers in this field, we ensure that our factory produces high-quality water-cooled chillers that meet the demands of various industries while providing reliable performance and energy efficiency.

    Product Details

    Industrial Cooling Laser Recirculating Water Cooled Chill

    High Efficiency and Energy Savings

    Water-cooled chillers are known for their superior energy efficiency compared to air-cooled systems. By utilizing water, which has a higher heat transfer capacity than air, they can dissipate heat more effectively, leading to lower energy consumption and operating costs in large-scale cooling applications.

    01
    Industrial Cooling Laser Recirculating Water Cooled Chill

    Better Heat Dissipation

    Water has a higher thermal conductivity than air, which allows water-cooled chillers to achieve more effective heat exchange. This results in better overall cooling performance, particularly in environments that require constant or large amounts of cooling, such as industrial processes and commercial buildings.

    02
    Industrial Cooling Laser Recirculating Water Cooled Chiller (3)

    Stable Temperature Control

    Water chillers provide more precise and stable temperature control, making them ideal for sensitive applications like pharmaceuticals, data centers, and laboratories, where consistent temperatures are crucial for optimal performance and safety.

    03
    Industrial Cooling Laser Recirculating Water Cooled Chiller

    Stable Temperature Control

    Compared to air-cooled chillers, water-cooled chillers typically have a more compact design, making them ideal for spaces where room for large equipment is limited. The system’s reliance on water rather than air means it requires less space for heat exchange surfaces.

    04

    Longer Lifespan and Reliability

    Water-cooled chillers tend to have a longer operational lifespan when properly maintained. Since water is a more efficient medium for heat transfer, the system experiences less wear and tear, leading to enhanced reliability and reduced maintenance requirements.

    05
    Technical Specifications
    Model CW3000 CW5200 CW5300 CW-6000
    Voltage AC 1P 110V AC 1P 110V AC 1P 110V AC 1P 220V
    Frequency 50/60Hz 60Hz 60Hz 50
    Current 0.4~0.9A 0.4~5.3A 0.5~8.9A 0.5~7.2A
    Machine power 0.1KW 0.43KW 0.77kW 0.98kW
    Compressor power / 0.38kW 0.66kW 1.06kW
    Nominal cooling capacity / 1.03kw 1.67kw 3.14kw
    Pump power / 0.03kw 0.05kw 0.05kW
    Max. lift 10m 10m 12m 12m
    Max.flow 10L/min 10L/min 13L/min 13L/min
    N.W. 8.7kgs 21.5kgs 22.7kgs 53kgs
    G.W. 11kgs 24.5kgs 25.7kgs 63kgs
    Precision / ±0.3℃ ±0.3℃ ±0.5℃
    Tank capacity 9L 6L 6L 15L
    Inlet and outlet OD 10mm barbed connector Rp1/2"
    Dimension 49 X 27 X 38cm 58 X 29 X 47cm 67 X 47 X 89cm (L X W X H)
    Package Dimension 59 X 38 X 47cm 65 X 39X 56cm 74 X 61 X 103cm
    Suitable laser tube power ≤80W 80W-120W 120W-130W Above 130W
    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Frequently Asked Questions

    What are the primary differences between the CW3000, CW5200, CW5300, and CW-6000 models?
    The main differences lie in their cooling capacity, machine power, and suitable laser tube power. The CW3000 is a heat-dissipation type chiller suitable for lasers ≤80W. The CW5200 (1.03kW capacity), CW5300 (1.67kW capacity), and CW-6000 (3.14kW capacity) are refrigeration-type chillers designed for higher-power laser tubes up to and above 130W.
    Why do water-cooled chillers offer better heat dissipation than air-cooled systems?
    Water has a significantly higher thermal conductivity and heat capacity than air. This enables water-cooled chillers to absorb and transfer heat away from the laser equipment much faster and more efficiently, maintaining optimal performance even in demanding environments.
    What is the temperature control precision of these recirculating chillers?
    The CW5200 and CW5300 models offer high-precision temperature control of ±0.3℃. The larger CW-6000 model operates with a temperature control precision of ±0.5℃, ensuring stable and consistent thermal conditions for sensitive applications.
    How do I choose the correct chiller based on my laser tube power?
    You can match your laser tube power with the recommended chiller specifications: use the CW3000 for laser tubes ≤80W, the CW5200 for 80W-120W, the CW5300 for 120W-130W, and the CW-6000 for laser configurations above 130W.
    What are the water tank capacities of these industrial cooling models?
    The CW3000 features a 9L tank capacity. The CW5200 and CW5300 models are equipped with a 6L water tank, while the high-capacity CW-6000 has a 15L water tank to support larger cooling cycles.

    Leave Your Message