CO2 Laser Power Supply for Laser Engraving Machine - China Suppliers & Factory Solutions
Product Details
Modular Design with Automatic Detection
The system features a modular design, which enhances flexibility and ease of maintenance. It is capable of automatically detecting both the laser power signal and water protection status. This ensures that the system can monitor the performance of critical components and alert the user to any irregularities, such as insufficient water flow or power fluctuations, providing a safeguard for the overall system's operation. The self-diagnostic capability reduces downtime and ensures continuous, reliable performance during operation.
Zero-Current Semi-Bridge Soft Switch Circuit
The power supply integrates a zero-current semi-bridge soft switch circuit, which plays a key role in optimizing energy efficiency and responsiveness. This innovative design minimizes switching losses, ensuring that the system operates with maximum efficiency while maintaining a fast response time. The soft switching mechanism significantly reduces electromagnetic interference (EMI) and extends the lifespan of the components, contributing to overall system stability and long-term reliability.
Simple Port Control with TTL Signal Compatibility
The control ports of the system are designed for simplicity and ease of integration, making it compatible with both high and low-level signals. Using a TTL-level signal, users can easily control the start and stop of the laser, offering precise control over the laser's operation. Additionally, the system includes an abnormal protection switch that monitors external water and air flow, ensuring that the necessary cooling and ventilation systems are functioning correctly, preventing damage due to overheating or insufficient airflow.
Adjustable Laser Power with Analog or PWM Signal Input
It can be adjusted the laser power though the 0 to 5V analog signal ,but also to input PWM signal to control the laser power.
Open Circuit Protection Function
The power supply has the function or open circuit protection. In the case of good grounding,the power supply can work in the open state for a shor time to avoid the damage caused by the burst of the laser tube.
Rigorous Testing for Reliability
Each power supply must be tested in 60℃ in a fuIl load condition and switched 500 times in 7 second.
Technical Specifications
| Model | Z50(50w) | Z60(60w) | Z80(80w) | Z100(100w) | Z120(120w) | Z150(150w) |
| Input Voltage | AC110V/220V | AC110V/220V | AC110V/220V | AC110V/220V | AC110V/220V | AC110V/220V |
| AC Frequency | 47-440HZ | 47-440HZ | 47-440HZ | 47-440HZ | 47-440HZ | 47-440HZ |
| Max. Output Voltage | 22KV | 24KV | 26KV | 28KV | 30KV | 32KV |
| Max. Output Current | 22mA | 25mA | 28mA | 30mA | 35mA | 38mA |
| Efficiency | ≥91% | ≥91% | ≥91% | ≥91% | ≥91% | ≥91% |
| High Level | ≥3V | ≥3V | ≥3V | ≥3V | ≥3V | ≥3V |
| Low Level | ≤0.7V | ≤0.7V | ≤0.7V | ≤0.7V | ≤0.7V | ≤0.7V |
| Dimension | 171*161*91 | 197*161*91 | 230*161*91 | 230*161*91 | 305*161*91 | 305*161*91 |
| Colour | Black | Black | Black | Black | Black | Black |
| Test time in 60℃ in a full load condition | 500 times | 500 times | 500 times | 500 times | 500 times | 500 times |
| Over-current Protection | 130%*Max.current | 130%*Max.current | 130%*Max.current | 130%*Max.current | 130%*Max.current | 130%*Max.current |
| Cooling | Forced air cooling | |||||
| Open Circuit Protection | Yes(In a short time) | |||||
| Leakage current to the ground | Amplitude 0.5mm.frequency 10-55HZ,3 dimension 2 hours | |||||
| Response Speed | AC 1500V 10mA 60s;Input-output,output-cover:AC1500v 10mA 60s;the output cathode is connected to the cover. | |||||
Frequently Asked Questions
How does the modular design benefit the laser power supply system?
The modular design enhances flexibility and makes maintenance much easier. It automatically detects both the laser power signal and water protection status, alerting users to issues like insufficient water flow or power fluctuations to safeguard the overall system.
What is the advantage of the Zero-Current Semi-Bridge Soft Switch Circuit?
This circuit design minimizes switching losses, optimizes energy efficiency, and ensures a fast response time. It also significantly reduces electromagnetic interference (EMI) and extends the overall lifespan of the components.
How can I control the laser power output?
You can easily adjust the laser power using either a 0 to 5V analog signal or a PWM (Pulse Width Modulation) signal input. Additionally, the system supports TTL-level signals for simple start/stop control.
Does the power supply offer open circuit protection?
Yes, the power supply includes an open circuit protection function. Under proper grounding conditions, it can operate in an open state for a short time to prevent damage caused by a laser tube burst.
What testing is performed to ensure the reliability of the power supply?
To ensure high reliability, each power supply undergoes rigorous testing in 60℃ environmental conditions under full load, and is switched 500 times within a 7-second interval sequence.