Inquiry
Form loading...
CO2 Laser Power Supply for Laser Engraving Machine - Top China Suppliers & Factory Solutions
Hot Products

CO2 Laser Power Supply for Laser Engraving Machine - Top China Suppliers & Factory Solutions

Introducing our advanced CO2 power supply system, a cutting-edge energy solution designed to generate electricity using carbon dioxide (COas a working fluid. This innovative technology not only offers a sustainable energy source but also plays a vital role in carbon capture and utilization (CCU) by effectively utilizing waste CO2 emissions from industrial processes. Our system is based on the efficient principles of thermodynamic cycles, specifically the supercritical CO2 (sCOBrayton cycle, which benefits from the exceptional properties of CO2 in its supercritical state. As a leading supplier in China, we are dedicated to providing top-quality CO2 power supply systems directly from our factory, ensuring an eco-friendly approach to energy generation while meeting the growing demand for sustainable industrial solutions

    Product Details

    CO2 Laser Power Supply for Laser Tube on Las (3)
    01

    Modular Design with Automatic Detection

    The system features a modular design, which enhances flexibility and ease of maintenance. It is capable of automatically detecting both the laser power signal and water protection status. This ensures that the system can monitor the performance of critical components and alert the user to any irregularities, such as insufficient water flow or power fluctuations, providing a safeguard for the overall system's operation. The self-diagnostic capability reduces downtime and ensures continuous, reliable performance during operation.

    CO2 Laser Power Supply for Laser Tube on Las (4)
    02

    Zero-Current Semi-Bridge Soft Switch Circuit

    The power supply integrates a zero-current semi-bridge soft switch circuit, which plays a key role in optimizing energy efficiency and responsiveness. This innovative design minimizes switching losses, ensuring that the system operates with maximum efficiency while maintaining a fast response time. The soft switching mechanism significantly reduces electromagnetic interference (EMI) and extends the lifespan of the components, contributing to overall system stability and long-term reliability.

    CO2 Laser Power Supply for Laser Tube on Las (5)
    03

    Simple Port Control with TTL Signal Compatibility

    The control ports of the system are designed for simplicity and ease of integration, making it compatible with both high and low-level signals. Using a TTL-level signal, users can easily control the start and stop of the laser, offering precise control over the laser's operation. Additionally, the system includes an abnormal protection switch that monitors external water and air flow, ensuring that the necessary cooling and ventilation systems are functioning correctly, preventing damage due to overheating or insufficient airflow.

    CO2 Laser Power Supply for Laser Tube on Las
    04

    Adjustable Laser Power with Analog or PWM Signal Input

    It can be adjusted the laser power though the 0 to 5V analog signal ,but also to input PWM signal to control the laser power.

    CO2 Laser Power Supply for Laser Tube on Lase- (1)
    05

    Open Circuit Protection Function

    The power supply has the function or open circuit protection. In the case of good grounding,the power supply can work in the open state for a shor time to avoid the damage caused by the burst of the laser tube.

    06

    Rigorous Testing for Reliability

    Each power supply must be tested in 60℃ in a fuIl load condition and switched 500 times in 7 second.

    Technical Specifications

    Model Z50(50w) Z60(60w) Z80(80w) Z100(100w) Z120(120w) Z150(150w)
    Input Voltage AC110V/220V AC110V/220V AC110V/220V AC110V/220V AC110V/220V AC110V/220V
    AC Frequency 47-440HZ 47-440HZ 47-440HZ 47-440HZ 47-440HZ 47-440HZ
    Max. Output Voltage 22KV 24KV 26KV 28KV 30KV 32KV
    Max. Output Current 22mA 25mA 28mA 30mA 35mA 38mA
    Efficiency ≥91% ≥91% ≥91% ≥91% ≥91% ≥91%
    High Level ≥3V ≥3V ≥3V ≥3V ≥3V ≥3V
    Low Level ≤0.7V ≤0.7V ≤0.7V ≤0.7V ≤0.7V ≤0.7V
    Dimension 171*161*91 197*161*91 230*161*91 230*161*91 305*161*91 305*161*91
    Colour Black Black Black Black Black Black
    Test time in 60℃ in a full olad condition 500 times 500 times 500 times 500 times 500 times 500 times
    Over-current Protection 130%*Max.current 130%*Max.current 130%*Max.current 130%*Max.current 130%*Max.current 130%*Max.current
    Colling Forced air cooling
    Open Circult Protection Yes(In a short time)
    Leakage current to the ground Amplitude 0.5mm.frequency 10-55HZ,3 dimension 2 hours
    Response Speed AC 1500V 10mA 60s;Input-output,output-cover:AC1500v 10mA 60s;the output cathode is connected to the cover.

    Frequently Asked Questions (FAQ)

    What are the advantages of the modular design in this CO2 laser power supply?

    The modular design increases flexibility and simplifies maintenance. It automatically detects the laser power signal and water protection status, alerting users to anomalies like low water flow to safeguard the system.

    How does the zero-current semi-bridge soft switch circuit improve efficiency?

    This circuit minimizes switching losses, leading to maximum energy efficiency and faster response times. It also reduces electromagnetic interference (EMI) and extends the lifespan of internal components.

    Is this power supply compatible with TTL control signals?

    Yes, the control ports are highly compatible with both high and low-level TTL signals, enabling simple and precise control over the laser's start and stop operations.

    How can I adjust the output power of the laser?

    The laser power can be adjusted flexibly using either a 0 to 5V analog signal input or a PWM (Pulse Width Modulation) signal input.

    What is open circuit protection and how does it protect the system?

    When properly grounded, the open circuit protection allows the power supply to operate safely in an open state for a short period. This prevents damage to the unit if the laser tube bursts.

    What reliability tests do these power supplies undergo?

    Each unit undergoes rigorous quality assurance, including testing under full load conditions at 60°C and being switched 500 times within a 7-second interval to ensure long-term operational stability.

    Leave Your Message